ALVIN PIPE LOAD CAPACITY CHART
|
SPAN
|
3/4"
Sch.40
|
1"
Sch.40
|
1 1/4"
Sch.40
|
1 1/2"
Sch.40
|
2"
Sch.40
|
|
2'-0"
|
676
|
1264
|
2248
|
3125
|
5372
|
|
3'-0"
|
450
|
843
|
1500
|
2083
|
3581
|
|
4'-0"
|
338
|
632
|
1124
|
1563
|
2686
|
|
5'-0"
|
270
|
505
|
900
|
1250
|
2149
|
|
6'-0"
|
225
|
421
|
749
|
1042
|
1790
|
|
7'-0"
|
193
|
361
|
642
|
893
|
1537
|
|
8'-0"
|
168
|
316
|
562
|
781
|
1343
|
|
9'-0"
|
150
|
281
|
500
|
694
|
1192
|
|
10'-0"
|
134
|
252
|
448
|
625
|
1074
|
Standard Schedule 40 Steel Pipe
Safety Factor of 2 : 1
NOTE:
- One pipe supporting an evenly distributed load
(Fig. 1)
- For cantilever pipes with evenly distributed
load, all figures to be multiplied by 0.166 (Fig. 2)
- For cantilever pipes with load at end, all figures
to be multiplied by 0.083 (Fig. 3)
- All Loads are in pounds (lbs.)
|
Span

Fig 1
|
Span

Fig 2
|
Span

Fig 3
|
|
|